Ex9 Series M1M 100 Ampere (A) Continuous Current S Interrupting - Lug Line/Load Side Connection Molded Case Motor Circuit Protector A complete range of 3 pole Molded Case Motor Circuit Protectors (MCPs, magnetic or short circuit protection only) whic
Secure Shopping
100% Safe Guarantee
Free Shipping
On orders over $30
Money-Back
30-Day Guarantee
A complete range of 3 pole Molded Case Motor Circuit Protectors (MCPs, magnetic or short circuit protection only) which are used to protect the cables feeding three phase motors in six frame sizes: M1M - 150 A, M2M - 250 A, M3M - 400 A, M4M - 600 A, M5M - 800 A, and M6M - 1200 A. Each frame size offers a range of interrupting ratings at 240-690Vac and 250-600 Vdc. 5-Year limited warranty.
Part Number: 1101423
Lug Line/ Load Side Connection MCP sold with Terminal Lugs
Continuous Current 100A
Full Load Current at Cam Setting A - 1.6 to 1.7A
Full Load Current at Cam Setting B - 1.8 to 1.9A
Full Load Current at Cam Setting C - 2.0 to 2.2A
Full Load Current at Cam Setting D - 2.3 to 2.4A
Full Load Current at Cam Setting E - 2.5 to 2.6A
Motor Circuit Protection (MCP) Trip Setting at Cam Setting A - 21
Motor Circuit Protection (MCP) Trip Setting at Cam Setting B - 24
Motor Circuit Protection (MCP) Trip Setting at Cam Setting C - 27
Motor Circuit Protection (MCP) Trip Setting at Cam Setting D - 30
Motor Circuit Protection (MCP) Trip Setting at Cam Setting E - 33
Rated Current at 480Vac, 65kA
S Interrupting - Lug Line/ Load Side Connection
Features:
The traditional system used for this purpose is based on three different devices: a circuit breaker for protection against short-circuit, a thermal relay for protection against overload and phase loss or unbalance of phase, and a contactor for motor switching. In particular, when selecting these devices, different factors must be taken into consideration, such as:
The motor power
The diagram and type of starting
The type of motor: with cage rotor or with wound rotor
The fault current at the point of the network where the motor is installed
Certifications:
UL 489 Recognized, File Number E355392 (Standard for connection terminals which allows the user to apply field wiring directly to the breaker)
Certified for Canada According to CSA Standards 22.2 No.5
IEC/EN 60947-2
CE Compliant
RoHS Compliant