Product characteristics Number of inputs and outputs Number of digital outputs: 1; Number of analog outputs: 1 Measuring range -1...16 bar -14.6...232 psi -0.1...1.6 MPa Process connection threaded connection G 1 external thread Aseptoflex Vario App
Secure Shopping
100% Safe Guarantee
Free Shipping
On orders over $30
Money-Back
30-Day Guarantee
Get Your Ifm Pm1714 Flush Pressure Sensor Unlock 40% Savings [FJEDVvcm]
Product characteristics
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Measuring range
-1...16 bar
-14.6...232 psi
-0.1...1.6 MPa
Process connection
threaded connection G 1 external thread Aseptoflex Vario
Application
System
gold-plated contacts
Measuring element
ceramic-capacitive pressure measuring cell
Temperature monitoring
no
Application
flush mountable for the food and beverage industry
Media
viscous media and liquids with suspended particles; liquids and gases
Medium temperature [°C]
-25...150
Min. bursting pressure
250 bar
3625 psi
25 MPa
Pressure rating
75 bar
1085 psi
7.5 MPa
Vacuum resistance [mbar]
-1000
Type of pressure
relative pressure; vacuum
No dead space
yes
MAWP (for applications according to CRN) [bar]
60
Electrical data
Operating voltage [V]
18...30 DC
Min. insulation resistance [MΩ]
100; (500 V DC)
Protection class
III
Reverse polarity protection
yes
Integrated watchdog
yes
2-wire
Current consumption [mA]
3.5...21.5
Power-on delay time [s]
1
3-wire
Current consumption [mA]
< 45
Power-on delay time [s]
0.5
Inputs / outputs
Number of inputs and outputs
Number of digital outputs: 1; Number of analog outputs: 1
Outputs
Total number of outputs
2
Output signal
analog signal; IO-Link; (configurable)
Number of digital outputs
1; (IO-Link)
Number of analog outputs
1
Analog current output [mA]
4...20; (scalable)
Max. load [Ω]
700; (Ub = 24 V; (Ub - 9 V) / 21.5 mA)
Short-circuit proof
yes
Overload protection
yes
Measuring/setting range
Measuring range
-1...16 bar
-14.6...232 psi
-0.1...1.6 MPa
Analog start point
-1...12.8 bar
-14.6...185.6 psi
-0.1...1.28 MPa
Analog end point
2.2...16 bar
32...232 psi
0.22...1.6 MPa
In steps of
0.01 bar
0.2 psi
0.001 MPa
Factory setting
ASP = 0.0 bar
AEP = 16.0 bar
Accuracy / deviations
Repeatability [% of the span]
< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)
Characteristics deviation [% of the span]
< ± 0,2; (linearity incl. hysteresis and repeatability, limit value setting to DIN EN IEC 62828-1)
Linearity deviation [% of the span]
< ± 0,15; (Turn down 1:1)
Hysteresis deviation [% of the span]
< ± 0,15; (Turn down 1:1)
Long-term stability [% of the span]
< ± 0,1; (Turn down 1:1; per year)
Total deviation over temperature range
Temperature range
total deviation
-25...15 °C
Characteristics deviation ± 0,05 % of the span / 10 K
15...80 °C
Characteristics deviation
80...150 °C
Characteristics deviation ± 0,1 % of the span / 10 K
Notes on the accuracy / deviation
for further details see section Diagrams and graphs
Reaction times
Damping for the analog output dAA [s]
0...4
2-wire
Step response time analog output [ms]
30
3-wire
Step response time analog output [ms]
7
Interfaces
Communication interface
IO-Link
Transmission type
COM2 (38,4 kBaud)
IO-Link revision
1.1
SDCI standard
IEC 61131-9
Profiles
Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)
SIO mode
no
Required master port class
A
Process data analog
What Our Customers Say
January 25, 2026
Absolutely no complaints!
A wonderful product, works wonders.
- Madelyn Y..
January 25, 2026
Absolutely no complaints!
Top-class item. I'm very satisfied.
- Paxton G..
January 25, 2026
Absolutely no complaints!
This is a quality product.
- Marion V..
Write a Review