- Type: Circuit breaker Masterpact NW30H
- Manufacturer: Schneider Electric
- Poles: 4P
- Neutral Position: Left
- Network Type: AC
- Breaking Capacity Code: H
- Frequency: 50/60 Hz
- Control Type: Push-button
- Mounting Mode: Drawout
- Rated Current: 3000 A
- Rated Operational Voltage: 240...600 V AC 50/60 Hz
- Breaking capacity:
- 100 kA at 240 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA at 480 V AC 50/60 Hz conforming to IEC 60947-2
- 85 kA at 600 V AC 50/60 Hz conforming to IEC 60947-2
- Protection Type: Without Protection
- Connection Pitch: 115 mm
- Rated Short-time Withstand Current: 65 kA / 1 s.
- Integral Instant Protection: 65 kA
- Maximum Breaking Time: 30 ms
- Maximum Closing Response Time: 70 ms
- Dimensions: 439 mm x 556 mm x 394.5 mm
- Standards: UL 489
- IP Degree of Protection: IP30

© Energy Power Systems LLC. 2021 - 2022
Our items are industrial surplus. Original packaging may have shelf wear or be damaged. The item itself will be new and unused.
- Type: Circuit breaker Masterpact NW30H
- Manufacturer: Schneider Electric
- Poles: 4P
- Neutral Position: Left
- Network Type: AC
- Breaking Capacity Code: H
- Frequency: 50/60 Hz
- Control Type: Push-button
- Mounting Mode: Drawout
- Rated Current: 3000 A
- Rated Operational Voltage: 240...600 V AC 50/60 Hz
- Breaking capacity:
- 100 kA at 240 V AC 50/60 Hz conforming to IEC 60947-2
- 100 kA at 480 V AC 50/60 Hz conforming to IEC 60947-2
- 85 kA at 600 V AC 50/60 Hz conforming to IEC 60947-2
- Protection Type: Without Protection
- Connection Pitch: 115 mm
- Rated Short-time Withstand Current: 65 kA / 1 s.
- Integral Instant Protection: 65 kA
- Maximum Breaking Time: 30 ms
- Maximum Closing Response Time: 70 ms
- Dimensions: 439 mm x 556 mm x 394.5 mm
- Standards: UL 489
- IP Degree of Protection: IP30